Cable construction :
Twin conductorTwin conductor :
Solid heating coreInsulation :
FluoroplasticProtective jacket :
PVCConnector :
Out spliceOutside diameter :
3.6mmRated voltage :
220V-240VLiner power :
12W/m or 15W/mResistance tolerance :
+10%/-5%The Electric Floor Heating Cable UTH can be used for ceramic tiles , natural stone and wooden floor etc. It's also suitable for either primary or secondary heat.
Technical Data:
Part NO. | Wattage (w) | Length(m) | Resistance(Ω) |
UTH-CABLE12-150 | 150 | 12.5 | 322.67 |
UTH-CABLE12-225 | 225 | 18.8 | 215.11 |
UTH-CABLE12-300 | 300 | 25 | 161.33 |
UTH-CABLE12-375 | 375 | 31.3 | 129.07 |
UTH-CABLE12-450 | 450 | 37.5 | 107.56 |
UTH-CABLE12-525 | 525 | 43.8 | 92.19 |
UTH-CABLE12-600 | 600 | 50 | 56.94 |
UTH-CABLE12-750 | 1000 | 62.5 | 80.67 |
UTH-CABLE12-900 | 900 | 75 | 53.78 |
UTH-CABLE12-1050 | 1050 | 87.5 | 46.10 |
UTH-CABLE12-1200 | 1200 | 100 | 40.33 |
UTH-CABLE12-1500 | 1500 | 125 | 32.27 |
UTH-CABLE12-1800 | 1800 | 150 | 26.89 |
We can provide customized production services according to your needs. The diameter and material of the cable can be customized according to your requirements.