HOMEAPPLICATIONIndustry heat traceSRS

  • SRS
  • SRS

SRS

The industry heat trace cable is a kind of industrial grade high temperature self-regulating heating cable that is ideal for large pipes /tanks and other industrial processes.Its systems with a high temperature impact on the tape.

Usage

It is an ideal solution for the projects that maintenance temperature. They keep the large pipes /tanks without insulation,down to -40 °C.

These heating cables are highly flexible and perfect for short heating circuits. As temperatures increase, the heater 's resistance increases which lowers the output wattage.

It constructed of a semi-conductive heater matrix extruded between parallel buss wires.

It constructed of a semi-conductive heater matrix extruded between parallel buss wires.

Free to contact us

  • Product Struction

  • Advantages & Applications

  • Technical Data

Product Struction

• Output Wattage:

15,30, 45, 60(W/m) at 10°C

• Maximum Un-energized temperature:

150°C

• Maximum Energized temperature:

110°C

• Minimum installation temperature:

-40°C

• Work voltage:

220V-240V

 

SRS Series

SRS2:

No Tinned copper metal & outer

 

SRS2-C

Tinned copper metal braid

 

SRS2-CF

Tinned copper metal braid and fluoropolymer outjacket

 

Partial view:

1. 1.37m㎡ copper conductors

2.Self-regulating conductive core.

3. Thermoplastic insulation.

4.Tinned copper braid

5.Fluoroplymer outer jacket(CF)/Thermoplastic outerjacket(CT)

 

Advantages

Easier installation, can be cut to any length (up to maximum circuit length) required on site with no wasted cable.
Lower installation cost than steam tracing and less maintenance expense as well as less downtime.
No overheat or burnout even when overlapped itself.
Ready to be used in non-hazardous, hazardous and corrosive environments.

SRS is ideally used for process maintenance and freeze protection of pipelines,tanks and other industrial application where high temperature is needed. It is suitable for hazardous area, also non-hazardous area and corrosive area. Fluoroplymer outer jacket will ensure products in good condition.

Technical Data

SRS Series:

Output Power@+

10°C(W/m)

Maximum

Energized

Maximum Un-

energized

Max

length@0°C

Max length@-

20°C 16/20A(m)

Size (mm)

Weight((kg/km)

15SRS2CF

15

110°C

150°C

110/144/-

98/128/-

12.9×6.45

154

30SRS2CF

30

110°C

150°C

68/98/-

60/90/-

12.9×6.45

154

45SRS2CF

45

110°C

150°C

54/84/-

48/78/84

12.9×6.45

154

60SRS2CF

60

110°C

150°C

42/68/82

38/62/72

12.9×6.45

154

Free to contact us